Here is the complete list of commands (see the signature in the DTH code, next to command's implementation for details about parameters):Ĭommand "setRoomUserDesiredTemp",Ĭommand "setRoomHumidityAwayMin",Ĭommand "setRoomHumidityAwayMax",Ĭommand "setRoomPreHeatPrecool",Ĭommand "setRoomFrozenPipePetProtect",Ĭommand "setRoomPucksInactive",.Support of US and metric scale systems (Celsius, Fahrenheit, etc)Ĭapability "Battery" // to be added later.With energy savings up to 30%, Flair’s Smart Vent keeps you-and your wallet-comfortable. Functionality:Works with your central heating and cooling system to eliminate uneven room temperatures across your home by automatically controlling how much air goes to each room.Manual mode enabled in the flair app (as you're letting your automation hub control the flair device(s), not Flair). Flair Setup completed: basic information about your home & rooms entered via the Flair Mobile App or the Flair portal.Flair Vent operational & connected to Flair via the Puck gateway.Puck gateway operational & connected to Flair via the internet.If you want to contribute more, here is the paypal link below. Technical support packages are also available. The Flair devices have required hundreds of hours of development & testing efforts to build, so a mandatory contribution fee 7.12 Issue #12: Some of my devices under the new Samsung app are disconnected.7.11 Issue #11: I want to change all scales to the metric system.7.10 Issue #10: .exceptions.ReadTimeoutException.7.9 Issue #9: : Execution time exceeded 'x' app execution seconds.7.8 Issue #8: I want to upgrade the code but I don't know how.7.7 Issue #7: I want to get more tracing in the IDE.7.6 Issue #6: "An unexpected error has occurred" or 'deleteObserver onError: %s' messages in MyFlairServiceMgr when I press 'Remove'.7.5 Issue #5: I want to disable any notifications from MyFlairServiceMgr.7.4 Issue #4: My Flair Vent is off by 'x' units with the Flair mobile app.7.3 Issue #3: I executed MyFlairServiceMgr smartapp, but the 3rd page (after doing the login, and pressing Next) is blank.7.2 Issue #2: I created My Flair Vent handler and MyFlairServiceMgr in the IDE, but I don't know where to execute it.7.1 Issue #1: I don't know how to create a custom device.6.6 Set level command may only work for 0% and 100%.6.3 Battery value is calculated, need to be replaced by value from Flair APIs.6.2 Not all Flair API fields are populated or properly set by Flair.6.1 UI elements are partially compatible with new STSC (Samsung) new app.
0 Comments
Leave a Reply. |